Coleman Gas Furnace Parts
More Coleman Parts
electric furnace parts,
blend air parts,
chimneys and ductwork,
a/c parts,
filters & misc
Other
generic parts,
furnace manuals,
Duo-Therm parts,
Goodman parts,
Nordyne parts,
electrical parts,
NOS parts,
ordering policies,
mobile home parts
|
To place an order, call us at 605-229-2627 (9-5 M-F). Or order online anytime. Same day shipping on most parts.
Search for your part.
Click here to troubleshoot your gas furnace.
Not sure which part you need, maybe our cheat sheet can help. Need help finding the right part, please e-mail us or call 605-229-2627.
TIP: To search for a part on this page, type 'Control F' and enter the part number or name.
| Blower Motors & Accessories |
|
7670-5391 Motor Mounting Bracket
Three-legged motor mounting bracket fits around motors that are about 4-5/8" to 5" in diameter. Approximate distance from center to center of mounting hole in legs is 10". Used with motor mounting package 2702-4091. Replaces 7670-6391. Your price $33.75.
|
 |
|
8680-5391 Motor Mounting Bracket
Mounting bracket fits around 5-5/8" motors. Approximate distance from center to center of mounting hole in legs is 10.5". Used with motor mounting package 2702-4091. Replaces 6321-5891, 6324-189, 6324-1891, 8680-539, 7700-5391, 6806-5891, 6324-1891, 2940-5491 & 026-34642-000. Your price $33.28 each.
|
|
|
2702-4091 Motor Isolator Kit
Motor mounting kit includes everything seen in photo. Three rubber gromets fit in a 3/4" hole. Used with motor mounts 7670-5391, 8680-5391 & probably others. Replaces 7670-3551, 026-34736-000, 026-34037-000 & 7660-3541. Your price $14.21.
|
 |
|
8865B1281 Isolator Kit
4 piece rubber isolator kit for mounting blower or booster motors. The rubbers themselves are 1/2" diameter x 1/2" long. The threads on the end are #8 course x 1/4" long. Replaces 8865A1281. Your price $41.52.
|
 |
|
024-26003-000 Blower Motor $99 generic motor available, see description.
3 speed 1/2 hp blower motor. 115V. 1110RPM. 10.7A. 48Y frame. Shaft size is 1/2" x 4.5". Housing is 5.5" diameter x 5" deep. Rotation is CCWLE (counter clockwise when looking at back/lead end). Wiring: white-common, red-low, blue-medium, black-high, browns-run cap. Requires run capacitor 024-20046-700 (not included). Replaces 02426003000, 024-27540-000, 024-25881-700, 024-25880-700, 024-25113-000, 024-25113-700, 024-23272-700, 024-25113-701, 024-23272-000, 024-23271-700, 024-23236-000, 024-23271-000, 024-21725-700, 024-23235-000, 024-21725-000, 024-21212-702, 024-21609-000, 024-21212-002, 024-21608-000, 024-18073-002, 024-18073-001, 024-17505-000, 024-22849-000, 8680-3239, B0603161, 2669-3239, 024-25223-700, 024-25223-000, 1468-428P, 1468-428 & 024-17416-000. Your price $208.04.
Or consider purchasing our S88-548 generic motor for $99 by
clicking here. Generic motor will work best if your able to reuse the mounting band of your existing motor. Otherwise a separate mounting band will need to be purchased. Some rewiring may be required.
|
 |
|
S88-544 Blower Motor
1/4hp, 1075rpm, 5-5/8" diameter, 1/2 x 5" shaft, 115V. This generic 3-speed motor replaces the following Coleman 1-speed motors that are no longer available: 8866-3159, 8866-315, 8866A3159, 8866A315, 7700-3119, 7700-311, 7700A3119, 7700A311, 7710-3119, 7710-311, 024-23071-000, 02423071000, 024-21620-000, 02421620000, 024-21620-700 & 02421620700. Connect to low speed using red and white wires. Connect brown wires to run cap. If motor turns backwards, switch the yellow and orange wires. Ignore all other wires. Requires run cap G21-930. Your price $99.00.
|
 |
|
|
S89-760 Blower Motor.
346 blower motor is an approved stock substitute for the motors listed below. 115V, 2 speed as wires can be switched (not shown), 1060RPM, 1/10HP, 4.8A. Shaft size 1/2" x 4.5". Housing 5" diameter x 4" deep. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Will fit mounting bracket 7670-5391. No run capacitor needed. Replaces motors 8665A311, 8665A3119, 8855B591, 8855B5911 Your price $171.89.
|
|
|
024-31948-000 Blower Motor
1/6 hp blower motor. 115V, 7.8A, 1000 RPM. 1/2" x 4.25" shaft. 5" motor diameter x 4.25" deep. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Fits many DGPA, DGPH and DGAH furnaces. No run cap required. Molex pins crimped onto the end of the wires. Pins then snap inside a Molex male plug. Order a replacement plug here. Also known as A.O. Smith B42A66A50. Your price $146.90.
|
 |
|
024-31949-000 Blower Motor
1/4 hp blower motor. 115V, 1050 RPM's. Requires run capacitor 1499-4461 (not included). Rotation is counter clockwise when looking from the back of the motor (CCWLE). Fits many DGPH090 and DGPA090 furnaces. Molex pins crimped onto the end of the wires. Pins then snap inside a Molex male plug. Order a replacement plug here. Your price $135.09.
|
 |
|
024-31950-000 Blower Motor
1/3 hp 2-speed 115V blower motor fits many DGAA furnaces. 1075 RPM, 6.5A. Shaft size is 3-3/8" x 1/2". Housing diameter is 4.75" x 4.25" deep. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Wiring: brown to run cap, black-high, red-low. Requires run capacitor 1499-4471 (not included). Molex pins crimped onto the end of the wires. Pins then snap inside a Molex male plug. Order a replacement plug here. Replaces 0243195000. Also known as A.O. Smith F42D85A50. Your price $169.30.
|
 |
|
024-35603-000 Blower Motor
2 speed 1/3 hp blower motor. Requires run capacitor 024-20063-700. 1075RPM, 42Y frame, 6.5A, 115V, rotation. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Includes 9-circuit mail molex plug. 5" motor diameter. 5" length including knob on shaft end. Shaft size is 1/2" x 3". Wiring: red-low, black-high, white-common, brown/white-run cap, brown-run cap. Replaces 1468-220, 1468-2209 & 1468-220P. Your price $156.42.
|
 |
|
1468-212P Blower Motor
1/4 hp blower motor. 115V, 1050 RPM, 6.0 amps, 42Y frame. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Requires run capacitor 1499-4461 (not included). 1/2" x 2.25" shaft. 5" housing diameter x 3-3/4" deep. Wires: brown-run cap, brown/white-run cap, black-hot, white-neutral. Wire ends equipped with molex male pins which snap inside molex plugs sold here. Replaces 1468-212 & 1468-2129. Your price $149.05.
|
 |
|
7966-311P Blower Motor
1/6 hp single speed blower motor. Requires no run capacitor. 115 volts, 1000 rpm, 7.8 amps, 60hz, 42Y frame. Shaft 1/2" x 2.25". Housing 5" diameter x 3-7/8" deep. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Molex pins crimped onto the end of the wires. Pins then snap inside a Molex male plug. Order a replacement plug here. Replaces 7966-311, 7966-3119, 7945-311, 7945-3119, 7945A311, 7945A3119, 7680A590, 7670-311, 7670-3119, 7656-311, 7660-311, 7660-3119, 7660A311, 7660A3119, 7670A311 and 7670A3119. Also known as A.O Smith 322P289. New Hot Price $99.00.
|
 |
|
1468-2309 Blower Motor
1/3hp blower motor. 115V. 3 speed. 1100 RPM. 5.0A. 1/2" x 3" shaft size. 5" motor diameter x 4" deep housing. Rotation is counter clockwise when looking from the back of the motor (CCWLE). Generally used with furnaces that have A/C. Wires can fit inside most plugs. Requires run capacitor 1499-4461 (not included). Molex pins crimped onto the end of the wires. Pins then snap inside a Molex male plug. Order a replacement plug here. Wiring: red-low, blue-medium, black-high, browns to run cap. Replaces 1468-230 & 026-34035-001. Your price $166.60.
|
 |
|
1468-235P/A Blower Motor $99 generic motor available, see description.
3 speed 1/2 hp blower motor for many 7600 furnaces with A/C. 115V. 1050RPM. Shaft size is 1/2" x 3-3/8". Housing is 5.5" diameter x 5" deep. Brown wires run to run cap, others from furnace plug into side of motor. Requires run capacitor 1499-4461 (not included). 115 volts. Replaces 1468-235A, 1468-235P, 1468-2359, 7660-3239, 7680-3239, 7680A3239 & 7670-3239. Your price $223.47,
Or consider purchasing our S88-548 generic motor for $99 by
clicking here. Generic motor will work best if your able to reuse the mounting band of your existing motor. You will also need to re-use the end that plugs into your existing motor. Otherwise a separate mounting band will need to be purchased. Some rewiring may be required.
|
 |
|
1468-236P Blower Motor $99 generic motor available, see description.
1/3hp blower motor. 3 speed, 1075rpm, 115V, 6.40A. Housing is 5-5/8" diameter x 5.5" long including knobs on end. Shaft is 1/2" x 3.5". Requires run cap 1499-4461 (not included). Wiring: run cap-brown, common-white, black-high, blue-medium, red-low, green/yellow-ground. Replaces 2755-312, 2755-3129, 1468-236, 1468-2369, 9336-423, 9336-4239, 8632-323, 8632-3239, 026-34732-000, 8632A3239, 2569H3311, 026-34035-002, 2632B3239, 2940-323, 2940-3239, B0603143, 2960-323, 2960-3239, 024-15821-000, 024-15815-000, B0603385, 024-22848-000, 024-15820-000, 026-28945-000, 024-17792-000, 024-17793-000, 024-21772-000, 024-18072-002, 024-17793-700, 024-21211-001, 024-23070-000, 024-21211-701, 024-21618-000, 024-23210-001, 024-23210-701, 024-25114-700, 024-25373-700, 02425112700 & 024-25112-700. Your price $181.65 each,
Or consider purchasing our S88-546 generic motor for $99 by
clicking here. Generic motor will work best if your able to reuse the mounting band of your existing motor. Otherwise a separate mounting band will need to be purchased. Some rewiring may be required.
|
|
Most orders are shipped the same day.
We ship most orders Priority Mail or UPS which generally arrive in 2-3 days.
|
|
7956A3771 Blower Control
Blower control. Replaces 7956-377, 7956-3771, 7956-3781 & 7956-378. Your price $70.57.
|
 |
|
2702-300P Blower Control Module
Blower control module, used in many upflow furnaces. Replaces 026-34030-000, 2895-300 & 2895-3001. Your price $110.95 each.
|
|
| Blower Wheels |
|
1472-2751 Blower Wheel
10 X 7 x 1/2" steel blower wheel ccw facing hub 48 blade. Double inlet single hub convex center plate. Maximum RPM 1750. Replaces 026-29682-000, 026-19654-710, 8631-3601, 7670-3601, 2567H335, 026-19654-010, 7670-3871, 2567H3351, 1472-2801, 026-34034-001, 026-24069-000 & 026-24069-700. Your price $105.24.
|
 |
|
1472-2761 blower wheel
10 X 8 x 1/2" steel blower wheel ccw facing hub 48 blade. Double inlet single hub convex center plate, 1 set screw. Replaces 7336-3701, 2568H335, 2568H3351, 9336-3751, 026-34731-001, B4308447, 026-26584-000, 026-34034-002, 026-26479-000, 026-23846-000, 026-21830-000, 026-16381-112, 026-14297-000, 026-19654-003 & 026-19654-703. Your price $81.33 each.
|
|
|
1472-2771 Blower Wheel
11 X 9 x 1/2" steel blower wheel ccw facing hub 54 blade. Double inlet single hub convex center plate, 1 set screw. Maximum RPM 1750. Replaces 8638-3801, 1472-277 & 026-36292-000. Your price $123.14.
|
 |
|
1472-2781 blower wheel
12 X 7 x 1/2" steel blower wheel ccw facing hub 43 blade. Double inlet single hub convex center plate, 1 set screw. Maximum RPM 1750. Replaces 7680-3891, 7680-3871, 7660-3601 & 026-36293-000. Your price $130.46 each.
|
|
|
1472-2791 Blower Wheel
9 x 7 x 1/2" steel blower wheel ccw facing hub 43 blade. Double inlet single hub convex center plate, 1 set screw. Replaces 7660-3631, 8865-3601, 7660-3871, 2681-2601, 1472-279, 026-29616-000 & 026-16381-141. Your price $88.97.
|
 |
|
|
|
We ship all our own parts. If you ever have a problem, you deal
directly with us, not a third-party drop-shipper.
|
| Booster Motors and Parts |
|
7956-5771 Combustion Air Damper Assembly
Combustion air damper assembly. Replaces 7956-321 & 7956-577. Your price $216.21
|
 |
|
7990-314P Booster Motor.
2900 RPM 120V Booster motor. Contains no centrifugal switch. Replaces 7990-314. Your price $68.98. Quick Tech Tip
|
 |
|
7990-317P/A Booster Motor/Centrifugal Switch
Combination booster motor and centrifugal switch. Centrifugal switch cannot be sold separately. Replaces 7990-317 & 7990-317P. Your price $120.58. Quick Tech Tip
|
 |
|
7995-3169 Booster Motor/Centrifugal Switch
Booster motor with centrifugal switch. Centrifugal switch cannot be sold separately. Replaces 7995-316, 7700B314, 7700B3149, 7724-316, 7724-3169, 7700A314, 7700A3149, 7700-314, 7700-3149, 7990-316, 8865-314, 8865-3149 & 8865-3141. Your price $157.37. Quick Tech Tip
|
 |
|
2940-391P Ventor Blower
Ventor blower assembly. 115V. 3000RPM. 1.3Amps. Replaces 2940-390, 2940-3901, 2940A390, 2940A3901, 2940B390, 2940B3901, 2940-391, 2940-390P/C & 2940-3901/C Your price $245.86. Quick Tech Tip
|
 |
|
7990-6501 Combustion Assembly.
Vent blower used on many furnaces with 'BDF' noted at the end of the model number. Includes housing, blower wheel, gasket and 7990-314P motor.
Your price $223.00. Quick Tech Tip
|
|
|
7990-6451 Booster Assembly
Booster assembly includes booster gasket, impellor, motor mount plate, 7990-317P/A booster motor & centrifugal switch. Brings air for combustion to the burner. Replaces 7990-645. Your price $241.50. Quick Tech Tip
|
 |
|
7995-6451 Booster Assembly
Booster assembly includes impellor, motor mount, 7995-3169 booster motor, centrifugal switch, mounting plate & booster gasket. Brings air for combustion to the burner. Replaces 7700B635, 7700B6351, 7700A635, 7700A6351, 7700-635 & 7700-6351. Your price $241.50. Quick Tech Tip
|
 |
|
373-19801-821 Booster Assembly with Motor
Booster assembly with motor. Brings air for combustion to the burner. Pressure switch 024-27666-001 not included. Replaces 373-19801-820, S1-37319801820 & S1-37319801821. Your price $127.66. Quick Tech Tip
View instruction sheet. |
 |
|
373-20717-001 Ventor Assembly
Ventor assembly with motor. Also referred to as a combustion or booster assembly. Pressure switches not included. Includes motor # 024-27641-000 which is not available separately. Used on furnace models DGAD060CD, DGAE080CD & DGAF100CD. Replaces 024-27641-000. Was $386.46, Your price $315.00. Quick Tech Tip
|
 |
|
2790-320P Booster Motor
Booster motor with 120V centrifugal switch. Brings air for combustion to the burner. 115V, 1000rpm. Your price $127.19. Quick Tech Tip
|
 |
|
2702-320P/A Vent Blower
Vent blower with 115V .02HP 3300 RPM motor. Replaces 2702-320, 2702-320P, 2702-321, 2702-321P, 2702-321P/A, 026-34024-000 & 026-34720-000. Your price $151.72.
|
|
|
W69-177 Blower Wheel
Replacement blower wheel for 7990-6451, 7990-6501 & 7995-6451 booster assy. 3-13/16" diameter x 1-7/8" width x 5/16" hole. Includes set screw. CCW when viewing from back plate. 3200RPM max. Your price $27.76.
|
|
|
|
|
|
024-27666-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. Closes at -.15" w/c when the combustion/booster motor is running. Switch will soon be updated to close at -.18". Original pressure on older switches was -.20". For replacement tubing, order B13-614 shown below. Replaces 024-27666-000, 025-41003-000, 025-41003-000, 025-41454-000 02541454000, 02427666000, 02427666001, 02541003000 & 02541003000. Your price $39.36.
|
 |
|
024-27637-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. 0.90 IWC on fall. For replacement tubing, order B13-614. Used on DGAD060CD furnaces. Replaces 024-35286-000, 02435286000, 024-27637-000 & 024-25995-000. Your price $27.45.
|
 |
|
024-27638-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. 1.0 IWC on fall. Used on DGAE080CD furnaces. For replacement tubing, order B13-614. Replaces 024-35261-000, 02435261000, 024-27638-000 & 024-25996-000.Your price $32.30.
|
 |
|
024-27632-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. -0.40 IWC on fall. Used on DGAD060CD & DGAE080CD furnaces. For replacement tubing, order B13-614. Replaces 024-27632-000 & 024-26038-000. Your price $25.14.
|
 |
|
024-27634-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. 0.65 Inches of Water Column (IWC). For replacement tubing, order B13-614. Replaces 024-27634-000 & 024-26000-000.Your price $26.83.
|
 |
|
024-27631-001 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. 0.20 Inches of Water Column (IWC). For replacement tubing, order B13-614. Replaces 024-27631-000 & 024-25993-000. Your price $26.22.
|
 |
|
024-35271-000 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. -0.50 Inches of Water Column (IWC). For replacement tubing, order B13-614. Replaces 2702-325P, 024-27629-001, 024-27629-000, 024-25808-701, 024-25808-001, 02435271000, 026-34722-001, 026-34026-002 & 024-27576-000 Your price $26.99.
|
|
|
024-27637-000 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. -0.90 Inches of Water Column (IWC) on fall. For replacement tubing, order B13-614. Replaces 024-27637-001, 024-25995-000, 024-35286-000 & 02435286000.. Your price $27.45.
|
 |
|
024-25994-000 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. -0.50 Inches of Water Column (IWC). For replacement tubing, order B13-614. Replaces 02425994000. Your price $37.66.
|
|
|
024-25285-000 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. -0.75 Inches of Water Column (IWC) on fall. For replacement tubing, order B13-614. Replaces 024-26001-000, 024-26001-001, 024-27635-000, 02426001000,02426001001, 02427635000 & 02435285000. Your price $27.45.
|
 |
|
2940-3151 Pressure Switch
Also referred to as a combustion air switch or draft proving switch. 24V, 0.30 Inches of Water Column (IWC) on fall. For replacement tubing, order B13-614. Replaces 2940-315, 024-35311-000 & 02435311000. Your price $48.39.
|
 |
|
B13-614 Silicone Tubing 12"
Clear 12" silicone tube. 1/8"id x 1/4"od. Stretches to fit tightly over most pressure switch nipples. Contact us for longer lengths. Also known as part number 028-11957-000 & 02811957000. Your price $3.92/ft
|
 |
Click here then type 'Control F' to search this page.
|
| Burner and Pilot Parts |
|
373-19801-403 DGAA Burner Assembly
Burner assembly found in many DGAA furnaces with auto ignition. Includes a 025-35354-000 flame sensor and a 1474-052P ignitor. Your price $190.78.
|
 |
|
Duo-Therm Flame Spreader 3-2861
Target flame spreader for a Duo Therm furnace. 6.5" distance from bolt to bolt. Round center is 3.25" diameter. Replaces H-2861. Your price $89.95.
|
 |
|
7970-5851/A HSI Burner Assembly
Burner assembly for furnaces with hot surface ignition. Includes burner, ignitor, flame sensor, shield & mounting plate. Replaces 7970-585, 7970-5851, 4066-565 and 4066-5651. Your price $117.95. Instructions.
|
 |
|
7945A5801 Burner Assembly
Burner assembly for furnaces with spark ignition. Includes burner, electrode with mounting bracket, wires & mounting plate. Replaces 4066-5541, 7945-5801 & 7945A5851. Your price $246.54.
|
 |
|
7945-1671/B Pilot Tube
Flexible pilot tube connects gas valve to pilot light. 17.75" long. Includes bracket and two ends. Also recommend replacing pilot burner, which is sold separately. Replaces 7945-1671, 7945-167, 7945-1671/A, 7660-1661 & 7660-166. Your price $40.54.
|
 |
|
7956A5851 Burner Assembly
Burner assembly includes pilot burner w/ pilot spud, pilot shield, thermocouple, 1/4" pilot tube, seal plate & mounting plate. Used on furnaces with a pilot light. Replaces 7956-585, 7956-5851 & 7956A585. IN STOCK! Your price $199.95.
|
 |
|
9880A0161 Pilot Burner w/ orifice
Pilot burner fits many furnaces and other appliances which have pilot lights like water heaters. Includes bracket, .016 pilot orifice, flame shield, thermocouple clip & compression nut. Used in both natural gas and propane (lp) appliances. Replaces 9880-0111, 9880-0161, 9958-0161 & 9958-016. Your price $16.48.
|
 |
|
9849-0161 Pilot Burner
Pilot burner fits many furnaces and other appliances which have pilot lights like water heaters. Includes bracket, pilot orifice, flame shield, thermocouple clip & compression nut. Used in both natural gas and propane (lp) appliances. Replaces 9942-0141, 9966-0161, 9966-0151, 9850A0161, 9850A0151, 9850-0161, 9850-0151 & 9849-0181. Your price $16.35.
|
 |
|
9815-0181 Pilot Burner
Pilot burner with orifice used in many 8600 series furnaces. NLA so limited to stock on hand. Your price $40.85.
|
 |
|
|
|
|
H85-428 26" Long Pilot Ignitor
26" long professional butane pilot lighter. Flame never blows out. 15" flexible tip plus 11" handle. Refillable, adjustable flame, safety lock, uses one AA battery (included). Great for lighting furnaces, water heaters, grills, fireplaces, candles, lanterns, etc. List price $99.00. Your price $79.00.
|
 |
|
2631-3481 Thermocouple 24"
Thermocouple senses pilot light and closes gas valve if none sensed. Used in most all furnaces with a pilot light. Replaces 2631-347, 2631-3471, 2631-348 & 026-34038-000. Sale price $15.21.
|
 |
|
025-30899-000 Sight Glass
Clear sightglass window plug for viewing the burner. Site snaps into a 7/8" hole. 3/8" deep.
Your price $4.95.
|
|
|
7970-5491 Burner Observation Door
Spring-loaded burner observation door with glass and gasket. Door covers an opening up to 2.5" diameter. With a little ingenuity, may work as a replacement for the old screw-on caps. Includes gasket number 7706A3171. Gasket available separately, just click on 'filters & misc' link at top of page. Screws not included. Replaces 7706-5491, 7706-549, 7706C5491, 7706C549, 7706B5491, 7706B549, 7706A5491, 7706A549 & 7970-549. No Longer Available.
|
 |
We offer a 1-year exchange warranty on all parts. Unlike other websites, we process the warranty claims for you.
|
| Control Boards and Modules |
|
7990-319P Integrated Control Board
Sometimes referred to as a circuit board or ignition control. For a spare or replacement fuse, order a 3A fuse G32-189 found below. Replaces 7956-319, 7956-319P, 7990-318, 7990-318/A, 7990-318P, 7990-318P/A & 7990-319. Was $171.00.
Your price $153.48.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
Diagnostic Flash Codes.
|
|
|
031-01909-000 Furnace Control Board
Circuit board used in all G8V & G9V upflow furnaces. White Rodgers model 50A51-243. Click on picture for an enlarged view.
Your price $287.79.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
|
|
7990-320P Integrated Control Board
Sometimes referred to as a circuit board or ignition control. For a spare or replacement fuse, order a 3A fuse G32-189 found below. Replaces 031-01910-000, 031-01932-000, 031-01932-001, 03101932002 & 031-01932-002. Your price $176.40.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
Diagnostic Flash Codes.
|
 |
|
1474-0061/A Ignition Module
Ignition module or ignition control. Replaces 1474-0061 & 1474-006. The difference between this module and the 1474-0041 is that this module supports a flame sensor. Was $124.26. Sale price $99.00.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
 |
|
1474-0041 Ignition Module
Hot surface ignition module or ignition control. Replaces 1474-0011, 1474-0021 & 1474-004. The difference between this module and the 1474-0061/A is that this module does not support a flame sensor. Your price $206.40.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
 |
|
7995-3081 Ignitor Module
Ignition module or ignition control. Replaces 7995-308, 7705-315 & 7705-3151. Your price $196.26.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
View the spec sheet.
|
 |
|
7956A3771 Blower Control
Blower control. Replaces 7956-3781. Your price $70.57.
|
 |
|
7970-378P/B Reignitor Module
Reignitor module 24AW080. Replaces 7970-378, 7970-3781, 7970-378P/A & 7970-378P. Your price $168.00.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
 |
|
373-23884-001 Ignition Control
Fenwall ignition control. 7 pin connector on side, 24V input. 15 second pre-purge, 15 second interpurge. Catalog number 35-605924-113 or 199-M89. Replaces 2940-325, 2940-3251 & 37323884001. Was $285.47 Your price $255.00.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
 |
|
|
|
|
6302-318P Furnace Control Module
Furnace control module. For a spare or replacement fuse, order a 5A fuse G32-043 found below. Replaces 025-32634-000, 1012-952 & 6302-318. Your price $195.88.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
|
|
2702-300P Blower Control Module
Blower control module, used in many upflow furnaces. Replaces 026-34030-000, 2895-300 & 2895-3001. Your price $110.95 each.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
|
|
|
431-01972-100 Integrated Control Board.
Furnace circuit board kit. Includes conversion kit (wires) 473-23151-000. Found in many BGU furnaces. For a spare or replacement fuse, order a 3A fuse G32-189 found below. Replaces 2702-310A, 2702-310P 2702-382P, 2702-380P, 2702-382P/A, 025-37014-000, 025-37015-000, 035-17344-000 035-17344-001, 43101972100, 431-01972-100, 473-01972-100, 473-23151-000. Your price $183.01.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
View the spec sheet.
|
 |
|
331-02956-000 Integrated Control Board
Furnace control circuit board kit. Used in many high efficiency 90% furnaces. For a spare or replacement fuse, order a 3A fuse G32-189 found below. Replaces S1-33102956000 S1-33109167000, 331-09167-000, 331-01972-200, 031-01972-000, 031-01140-000, 031-01235-000, 031-01267-000 031-01140-701, 031-00662-000, 031-01235-700, 031-01140-702, 031-00662-700, 031-01250-000, 031-01234-700, 031-01266-000, 031-01267-000, 031-01933-000 & 031-01267-001. Your price $132.95.
SAVE MONEY! We may be able to REPAIR YOUR OLD BOARD for a fraction of the cost of buying new. Click Here for more info.
View the spec sheet.
|
 |
|
G32-189 3 Amp Fuse.
3A ATC fuse found on some circuit control boards. Rated up to 32V. Also known as part number ATC-3, G32-644, 025-32746-026 & 02532746026. Your price $2.24.
|
 |
|
G32-043 5 Amp Fuse
5A ATC fuse found on some circuit control boards. Rated up to 32V. Also known as part number ATC-5, B1170553, 025-30382-700 & 02530382700. Your price $2.24.
|
 |
We are one of the few websites with experienced
HVAC technicians on staff to answer your questions.
|
| Fan and Limit Switches |
|
025-27792-001 Flame Rollout Switch
Temperature control switch with manual reset, L200F. Size 36TX16. Replaces 02527792001. Your price $9.12 each.
|
 |
|
025-29041-005 Limit Control
Limit control switch. L140-30F. Size 36T01B3. Back plate measures 1-7/8" x 2-3/4" with two 1/4" spade terminals. 3" arm length. Replaces S1-02529041005. Your price $17.42.
|
|
|
025-31813-000 3" Limit Switch
Limit control switch. L160-30F or L160F-30. Size 36T01B3. Back plate measures 3/4" x 2-3/8" with two 1/4" spade terminals. 3" arm length. Replaces 02531813000. Also known as part # 36T01B3-44697 and 1NT23L-2647. Was $10.10 Sale price $6.12 each.
|
 |
|
025-31814-000 3" Limit Switch
Limit control switch. L150-30F or L150F-30. Size 36T01B3. Back plate measures 3/4" x 2-3/8" with two 1/4" spade terminals. 3" arm length. Replaces 02531814000. Also known as part # 36T01B3-44698 and 1NT23L-2647. Your price $12.59 each.
|
 |
|
026-32588-017 Burner Limit Switch
Flame roll out switch. Manual reset. L350F. Size 36TX16. Replaces 4035300 & 02632588017. Your price $31.72 each.
|
 |
|
|
|
|
2702-3191 Rollout Limit Switch
Flame roll out control senses when the flame 'rolls' out of the combustion chamber, shutting down the overfired burner. Manual reset. L300F. Size 1NT08L-3182 Replaces 2702-319, 026-34723-000, 026-34027-000, 02634723000 & 02634027000. Your price $7.75 each.
|
 |
|
2845-3171 Fan Switch
Fan switch. F105-10F. Size 60T12. Your price $13.69.
|
|
|
2845-3191 Limit Switch
Limit switch with manual reset. L195F. Size 60T. Replaces 2845-319, 8865-326, 8865-3261, 8865A326 & 8865A3261. No longer available.
|
|
|
2940-3191 Flame Rollout Switch
Flame roll out switch. Manual reset. L300F. Size 60T14. Replaces 2840-3191, 2840-319 & 2940-319. Your price $16.26.
|
|
|
7710-3281 Fan & Limit Switch
Fan & limit switch. F105-20F. Size 60T82. Replaces 7710-328. Your price $12.89.
|
 |
|
8866-3281 Fan Switch
Fan switch. F130-35F. Size 60T82. Replaces 8866-328, 6806A3341 & 6806-3341. It is also the closest replacement for 8865A-328, 8865A-3281, 8635-3281, 8635-328, 8665-3271, 8665-327, 8665-3281, 8665-328, 8871-3281, 8871-328, 8865A3281 & 8865328. Your price $13.07.
|
 |
|
7975-3281 Fan Switch
Fan switch. F110-20F. Size T-0-D60T82 or 60T82. Replaces 7660-328, 7660-3281, 7956-335, 7956-3351, 7966-327, 7966-3271, 7700-328, 7700-3281, 4066-328, 4066-3281, 7975-328, 7995-355, 7995-3551, 8665B328, 8665B3281, 8665-332 & 8665-3321. Your price $13.52.
|
 |
|
7995-3281/A Limit Switch
Limit switch shuts down gas valve if overheating occurs. L150-30F. Size 36TX41. Used in many 95,000 BTU furnaces. Replaces 7995-328, 7995-328/A & 7995-3281. Your price $8.00.
|
 |
|
7945-3281/A Limit Switch
Limit switch shuts down gas valve if overheating occurs. L140-30F. Size 1NT01EL-2783 or 36TX41. Used in many 56,000 BTU furnaces. Replaces 7945-328, 7945-328/A & 7945-3281, 7945-328/A, 025-27727-003, 025-35380-000, 02527727003 & 02535380000. Your price $22.16.
|
 |
|
7970-3281/A Limit Switch
Limit switch shuts down gas valve if overheating occurs. L145-30. Size 1NT01EL-2784 or 36TX41. Used in many 70,000 BTU furnaces. Replaces 025-35381-000, 7970-3281, 7970-328/A & 7970-328. Your price $7.21.
|
 |
|
7700-3591 Limit Switch
Lower limit switch shuts down gas valve if overheating occurs. L165-30F. Size 60T11. Also known as part # 025-35381-000. Replaces 7700-359, 3200-3281 & 6804-3321. Your price $13.50.
|
 |
|
7705-3591 Limit Switch
Limit switch shuts down gas valve if overheating occurs. L145-20F. Size 60T11. Replaces 7705-359. Your price $13.14.
|
 |
|
7624A3591 Upper Limit Switch
Upper limit switch shuts down gas valve if overheating occurs. L180F degrees manual reset. Size 60TV15. Replaces 7624-A359, 7624-359, 7624-3591, 7675-359, 7724-3791, 7706A3591, 7706-3591 and 7675-3591. Your price $13.71.
|
 |
|
7990-3591 Limit Switch
Limit switch shuts down gas valve if overheating occurs. L180-30F. 1NT01EL-2782 or 36TX41. Replaces 7990-359. Your price $7.51.
|
 |
|
7660-3591 Limit Switch
Limit switch shuts down gas valve if overheating occurs. L150-20F. Size 60T11. Replaces 7660-359, 7724-359 & 7724-3591. Your price $13.75.
|
 |
|
7680-3591 Upper Limit Switch
Upper limit switch shuts down gas valve if overheating occurs. L155-20F. Size 60T11. Replaces 7680-359. Your price $12.68.
|
 |
|
025-35358-000 Limit Switch
Upper limit switch shuts down gas valve if overheating occurs. 150F. Size 1NT08EL-4052 or 36TX41. Manual reset. Replaces 02535358000. Your price $17.35.
|
 |
|
7680-3791 Upper Limit Switch
Upper limit switch shuts down gas valve if overheating occurs. L140-20F. Size 60T11. Replaces 7680-379. Your price $12.68.
|
 |
|
8866-3291 Limit Switch
Limit switch shuts down gas valve if overheating occurs. L135F. Manual reset. Size 60T15. Replaces 8866-329, 8866-326 & 8866-3261. Your price $13.55.
|
 |
|
6806-3351 Limit Switch
Limit switch shuts down gas valve if overheating occurs. L150-35F. Size 60T11 or 20601L65-663. Replaces 6806-335, 8880-3271, 8866-3271 & 8880A3271. Your price $18.43.
|
 |
Our network of back-up suppliers help keep out-of-stocks to a minimum.
|
| Flame Sensors and Ignitors |
|
025-35354-000 Remote Flame Sensor
Senses whether or not the burner is firing. Your price $21.03. Quick Tech Tip
|
 |
|
2631-3481 Thermocouple 24"
Thermocouple senses pilot light and closes gas valve if none sensed. Used in most all furnaces with a pilot light except those with a sparker. Your price $15.21.
|
 |
|
7975-388P/A Remote Flame Sensor
Senses whether or not the burner is firing. Replaces 7975-3881 & 7975-388. Was $67.88. Overstock price $49.09. Quick Tech Tip
|
 |
|
1474-052P Hot Surface Ignitor
Glows to light burner. 120V. Fragile. Do not touch with bare hands while installing. Replaces 1474-051, 1474-0521, 02541021000 & 025-41021-000. Was $44.50 Sale $39.50.
|
 |
|
7995-3061 Electrode Sparker
Sparker with flame sensor. Your price $67.13. Quick Tech Tip
|
 |
|
7970-377P Electrode Sparker
Electrode emits a spark to ignite pilot light. Your price $51.30.
|
 |
|
025-32625-000 Ignitor
Ignitor glows and lights burner. Fragile. Do not touch with bare hands while installing. Used on DGAD060CD, DGAE080CD & DGAF100CD furnaces. Also known as model number 271N & 271NM. Replaces 025-32626-000, 025-31801-000, 025-30277-700, 025-31802-000 & 025-30385-700. Your price $40.17.
View Conversion Instructions |
 |
|
025-30788-700 Flame Sensor
Flame sensor shuts down gas valve if no flame sensed. 5" total length. Bare sensing rod measures 1.75". Used on DGAD060CD, DGAE080CD & DGAF100CD furnaces. Replaces 025-30788-000, 02530788000 & 02530788700. Your price $22.00. Quick Tech Tip
|
|
|
2667-3051 Electrode Assembly
Electrode assembly often used in residential furnaces. Your price $98.55.
|
 |
|
2702-311P Sensor Rod
Sensor rod senses flame. 3" long, bent end is 2.25" long. Replaces 2702-311. Your price $18.07. Quick Tech Tip
|
|
|
2940-3041 Electrode Assembly.
Electrode assembly. Measures 6.25" long. Replaces 2940-304, 2940-3051, 2940-305 & 22-100000-614. Your price $92.73.
|
 |
|
025-27773-700 Flame Sensor
Flame sensor. Total lengh is 4". Sensing rod is 2.5" long. Replaces 02525434700 & 02525434000 02527773000, 025-25434-700 & 025-25434-000. Your price $21.00. Quick Tech Tip
|
 |
|
785-001 Automatic Pilot Relight Kit.
Pilot light reignitor kit automatic lights pilots that blow out. Operates on either 120 or 24 volt. Instructions show hooking up both power sources, but we'd recommend only hooking up 1 power source. Includes bracket for connecting sparker near pilot light. Removing burner/pilot assembly and drilling screw holes may be required. Also includes 105C appliance wire and ends (not shown) for connecting ignitor to power. This is an after-market part. Although frequently added to all types of appliances with pilot lights such as furnaces, water heaters, space heaters, dryers, stoves etc, most manufacturers do not recommmend using after-market add-ons and will general void any warranty. Replaces 7700AAF526. Your price $75.75.
Installation instructions |
 |
|
|
|
Click on picture for an enlarged view.
|
| Gas Valves |
|
025-43627-000 Gas Valve
White Rodgers 36J29-701 gas valve used on most Coleman furnaces with electronic ignition. Once again Coleman has updated the style so it may not look anything like your old gas valve. Convertible to natural gas or propane by reversing a stem. 1/2" gas inlet on right, 3/8" outlet on back left. Click on picture for top view. Replaces 7990-326, 7990-3261, 7990-326P, 7990-328, 7990-328P, 7707-326, 7707-3261, 7707-326P, 7C5C7F026, 36C76 & 36E29-101. Your price $101.67. Info Sheet |
 |
|
7956-336P Gas Valve
Gas valve used on many Coleman furnaces with a standing pilot light. Natural gas or propane. 1/2" gas inlet on right, 3/8" outlet on back. A new 2631-3481 thermocouple recommended (sold separately). Replaces 36C67, 36C87, 7656-356, 7656-3561, 7656A346, 7656A3461, 7956-336, 7956-3361, 7656-326, 7656-3261, 7656A326, 7656A3261, 7656-346, 7656-3461, 7660-326, 7660-3261, 7680-346, 7680-3461, 7631A326, and 7631A3261. Your price $162.42.
|
 |
|
7700A3461 Gas Valve
Gas valve often used on 7700 series Coleman furnaces. 1/2" inlet on right, 1/2" oulet in back. Natural gas or propane. Some older furnaces may require a different mounting bracket. If so use bracket number 7705-5101. Replaces 36C02 type 278, 7700-346, 7700-3461, 7700A346, 8680-401, 8680-4011, 7700-326, 7700-3261, 7700-356, 7700-3561, 7700-556 and 7700-5561. Your price $181.39.
|
 |
|
2736-326P Gas Valve
Gas valve found in many CGU furnaces and others. Natural gas only. 1/2" gas inlet on left, 1/2" gas outlet in back. Replaces 2940A3261, 2940A326, 2940-3261, 2940-326, 2940-3271, 2940-327, 2940-3261 2940-326, 2736-3261 & 2736-326. Your price $125.70.
|
 |
|
8955-3251 gas valve
Gas valve, 24V. Natural gas or propane. Replaces 8955-3261, 8955-326, 8955-325 & 36c77. A new 2631-3481 thermocouple recommended. Your price $163.58.
|
 |
|
325-37426-000 Gas Valve.
Gas valve found on many BGU furnaces. Replaces 025-35316-000, 025-35317-000, 025-31996-000, 025-31969-000, 025-32643-000, 026-32643-000, 2702-331P & 2702-326P. Your price $115.60.
|
|
|
720-007 Universal Gas Valve
Combination gas valve specifically designed for mobile homes with a constant pilot. Replaces most old or discontinued gas valves with pilot light. Features a 1/2" front and side inlet, 1/2" front and side outlet. Full wave (full open). Seal the unused inlet & outlet with the included 2 plugs. Also includes 2 bushings to reduce threads to 3/8". 24V. Natural gas or propane. A new 2631-3481 thermocouple is recommended (sold separately). Mounting brackets & orifices also sold separately. Your price $244.00. View instruction sheet.
|
 |
|
720-079 Universal Elec Gas Valve.
Universal gas valve for furnaces with intermittent pilot, hot surface or direct spark ignition. Does not work with continuous pilot. Does not replace smart valves. Comes set to Natural Gas but is convertible to propane (LP). Manometer needed to set the LP pressure. Features a 1/2" back and side inlet, 1/2" front and 3/4" side outlet. Full wave (full open). Seal the unused inlet & outlet with the included 2 plugs. Also includes 1 bushings to reduce 3/4" outlet to 1/2". 24V. Your price $160.37. View instruction sheet.
|
|
|
7660A1851 Orifice Spud
Orifice spud found on many 7600 series furnaces with the old style gas valves. Measures 2.25" long. 3/8" male threads on one end, 3/16" female orifice threads on the other. Orifice not included. Replaces 7660A185, 7660-1851, 7660-185 & 1031801. Your price $18.20.
|
|
|
78075 Manometer Gas Pressure Gauge
Manometer is a tool for checking gas pressure. Measures from -2 to 15 inches of watercolumn (wc). To operate, shut off furnace and gas. Fill cylinder with water to zero mark. Unscrew cap and connect tube to pressure port on gas valve. Turn on gas and furnace. Adjust pressure according to manufacturer instructions on gas valve. When done, shut off furnace and gas, remove tube from gas valve, screw cap back on pressure port, turn gas and furnace back on. Check for leaks. Your price $49.50.
|
|
|
7945-1631/A Gas Valve Mounting Plate
6" diameter gas valve mounting bracket. Contains one 5/8" hole, and two 9/16" holes. Replaces 7945-1631. Your price $16.14.
|
 |
|
7945-5151/C Gas Valve Mounting Bracket
Bracket for mounting gas valves such as the 7956-336P and 7990-328P to furnace wall. The threaded end of nipple screws into the gas valve while the orifice (not included) screws into the other end of nipple. Replaces 7945B5151 & 7945-5151. Your price $22.75.
|
 |
|
7705-5101 Gas Valve Mounting Bracket
Mounting bracket used with 7700A3461 gas valve and others. Plate measures 5"x4". Gas valve attaches to plate via 3/8" x 2.25" nipple. Orifice (not included) screws into opposite end of nipple. Mounting screws not included. Replaces 7656-511, 7656-5111 & 7705-510. Also replaces 7710-5101 using an included adapter. Your price $33.99.
|
 |
|
373-19801-064 Gas Valve Mounting Bracket
Gas valve mounting bracket used on many DGAA furnaces. Bracket is 6.75" wide x 3.5" tall. Replaces 073-19801-064 & 373-19801-063. Your price $32.60.
|
 |
|
Orifice - Natural Gas
Brass 3/16" orifice installs on gas valve for a natural gas furnace. When ordering, note the model number of furnace or size of orifice in the shopping cart notes or send a separate e-mail. Your price $9.00.
All sizes of orifices are available, even discontinued sizes as we custom make those for you. View sizing charts HERE. Order your own orifice drill bits HERE. Call or send us an e-mail if questions. We can get or make orifices for almost anything and everything.
|
 |
|
Orifice - Propane (LP)
Brass 3/16" orifice installs on gas valve for a propane (LP) furnace. When ordering, note the model number of furnace or size of orifice in the shopping cart notes or send a separate e-mail. Your price $9.00.
All sizes of orifices are available, even discontinued sizes as we custom make those for you. View sizing charts HERE. Order your own orifice drill bits HERE. Call or send us an e-mail if questions. We can get or make orifices for almost anything and everything.
|
 |
| Relays & Contactors |
|
7975-3771 Relay
White Rodgers 5 terminal relay. Terminals 4 & 5 are normally closed. When 24V terminals 1 and 3 are activated, it opens terminals 4 & 5 and closes terminals 2 & 5. Up to 277 volts, 3 amp.
Replaces 134-20103-301D, 6313-227, 6313-2271, 7975-377, 8680-435 & 8680-4351. Your price $28.97.
|
 |
|
3110-3311/A Relay
White Rogers 4 terminal relay. When 24V terminals 1 and 3 are activated, it opens terminals 4 & 5 to break the circuit. Sometimes known as a reversing relay. 3 amp, up to 277 volts. Also sometimes used as a thermostat or ignitor relay. Replaces 134-40102-206A, 7970-331 and 3110-3311. Your price $25.05.
|
 |
|
8665-5701 Booster Relay
Same relay as 7956-3671 but includes an updated wiring diagram required for some older furnaces. Also replaces 8665-570. Your price $31.50.
Wiring diagram.
|
 |
|
7956-3671 Relay
White Rodgers 4 terminal relay. When 24V terminals 1 and 3 are activated, it closes terminals 2 & 5 to complete the circuit. 3 amp, up to 277 volts. Often used for booster motors. Replaces 8665-309 & 7956-367. Your price $27.49.
|
 |
|
7670-3071 A/C Reversing Relay
Reversing relay/sequencer used with A/C's. Also replaces 7670-308, 7670-3081, 7670-310, 7670-310, 7670-3101, 7670-307, 7670-309, 7670-3091 and 7670-308. Your price $25.07.
|
 |
|
6313-2281 Blower Relay
Blower relay often used with A/C's. Replaces 024-26548-700, 6313-228, 7442-330 & 7442-3301. Your price $12.82.
|
 |
|
024-32004-000 Contactor
Contactor used in many Presidential gas furnaces and some a/c units. 277V, 2 pole, 30 amp, 24V coil. Replaces 02432004000, 024-14808-000, 024-14808-700, 024-19634-000, 024-16417-000, 024-16417-700, 024-25003-000, 024-25003-700, 6922-3131, 6922-313, 692-3131, 7431-313, 7431-3131, 7431-3131/A, 024-18056-001, 024-18056-701 & 024-25838-700. Your price $20.96.
|
 |
|
|
|
We sincerely hope that the information and service we've provided
will earn your business. Thank you for your patronage.
|
| Run Capacitors |
|
1499-4461 Run Capacitor
Run capacitor holds electrical charge to help start blower motor. 7.5MFD, 370 Volts. New part number will soon be 024-20045-700. Replaces 1499-3091, 1499-3481, 1499-4481, 6213-1701, 6213A1701, 1499-4461, 4070-2691, 4070A2691, 1499-346, 1499-3461, 1499-3071, 6563-3201, 6163-3201, 3110-3141, 1499-5071, 026-34730-001, 026-34033-001, 024-21780-000, 4036000, 024-23128-000, 024-20044-000, 026-32588-030, 024-20045-700, 02420045700 & many others.
Your price $8.04.
|
 |
|
024-20063-700 Run Capacitor
Run capacitor holds electrical charge to help start blower motor. 7.5MFD, 440 volt. Square plastic cap measures 2.25" x 1 3/8" x 7/8". Replaces 02420063700, 024-35602-000, 02435602000. Your price $11.20.
|
 |
|
1499-4471 Run Capacitor
Flat metal run capacitor holds electrical charge to help start blower motor. 7.5MFD, 440 Volts. Measures 2.25" x 2" x 1.25". Replaces 1499-447, 1499-447, 024-20063-000, 024-20063-700, 024-32020-000, 1499-347, 1499-3471, 024-20063-000, 02420063700 & 02432020000.
Your price $11.20.
|
 |
|
024-20046-700 Run Capacitor
Run capacitor holds electrical charge to help start blower motor. 10 MFD, 370 volt. Flat metal cap measures 2.75" x 2" x 1.25". Replaces 1499-3491, 1499-349, 1499-4491, 1499-449, 026-34730-002, 026-34033-002, 024-25908-000, 024-25054-700, 024-21774-000, 024-25908-700, 025-38626-000, 024-20046-000 & 02420046700 Your price $9.22.
|
 |
|
1499-4601 Run Capacitor
Flat metal run capacitor holds electrical charge to help start blower motor. 10MFD, 440 Volts. Measures 4" x 2" x 1.25". Replaces 6213A166, 6213-1661, 6213-166, 1499-361, 1499-3611, 1499-3601, 1499-360, 6213A1661, 1499-5111, 1499-511, 1499-460, 024-19328-000, 024-07555-000, 024-20065-000, 024-20065-700 & 02420065700.
Your price $14.44.
|
 |
|
G21-930 Run Capacitor
Oval run capacitor, 5 MFD 370V. Can measures 1.25" x 2 x 1.5" tall. Your price $4.95 each.
|
 |
| Switches |
|
7670-3521 Heat/Cool Switch
2 position heat/cool switch, 6 terminals. Face measures 1-1/8" x 1-1/4". Your price 19.14 each.
|
 |
|
7670-3531 Cont/Auto Switch
2 position continuous/auto switch, 2 terminals. Face measures 1-1/8" x 1-1/4". Your price $9.61 each.
|
 |
|
7681-3301 Toggle Switch
2-position toggle switch, 2 terminals. Face measures 11/16" x 1-1/4". Your price 7.61 each.
|
 |
|
|
|
| Thermostats |
|
025-38252-000 2-wire thermostat
Thermostat used on all Coleman furnaces with 2 wires at thermostat including units with A/C. Replaces 025-35368-000, 7966-375P, 7975-375P, 3400-3851, 7700-3751 & 7700-375P. Your price $27.01.
|
 |
|
025-38747-000 4-wire thermostat
Heat/AC thermostat used on all Coleman furnaces with 4 wires at thermostat. Replaces 7900-7541/A, 7900-7541, 7990-368P, 7670-3681/A & 7670-368P. Your price $35.57.
|
 |
| Transformers |
|
2940A3541 Transformer
115 volt input, 24 volt output, 40VA. Replaces 2940A354, 7660A350, 7660A3501, 7660B350, 7660B3501, 7660C350, 7660C3501, 7707-350 & 7707-3501. Your price $59.11.
|
 |
|
7945-3551 Transformer
115 volt input, 24 volt output, 15VA. Your price $27.99.
|
 |
| |
Click Here to request a quote on a Coleman part you don't see listed.
Please include part number (if known) and model number of furnace.
You will receive a response within hours.
Please note that some older part numbers do change, which we can help you with.
Need help finding the right part, please e-mail us.
Need help troubleshooting your furnace, please click here.