Re: Intertherm feh-020ha-04 electric heat+ air conditioner
Thanks Dale, Yes it has sequencers. Its just a normal forced air electric heat split system. Two 10kw heat coils. Like the Nordynes and colemens. I just always thought the heat coils cut off a few seconds before the fan shut down. I think my question is, if the heat coils and fan shut down at the sa...
- Sun Jan 12, 2014 4:44 pm
- Forum: Service & Repair of Other Brands
- Topic: Intertherm feh-020ha-04 electric heat+ air conditioner
- Replies: 4
- Views: 23698
Re: Intertherm feh-020ha-04 electric heat+ air conditioner
Is this area not active any more? Can someone move my post to a active category please?
- Wed Jan 08, 2014 4:41 pm
- Forum: Service & Repair of Other Brands
- Topic: Intertherm feh-020ha-04 electric heat+ air conditioner
- Replies: 4
- Views: 23698
Intertherm feh-020ha-04 electric heat+ air conditioner
Problem:Heating coils staying on at the cool down cycle. Replaced bad hunter t-stat(batteries not making good contact) with Honeywell-rth-111 series t-stat. When t-stat set temp is reached t-stat turns heat coils off, but they are really still on. Once a little time passes fan and heat elements turn...
- Thu Jun 27, 2013 6:26 pm
- Forum: All Other HVAC Questions
- Topic: Is this possible?
- Replies: 1
- Views: 5165
Is this possible?
Say someone has a 28x66 double wide and they put one large window unit in the living room. The central air does not cool but the blower fan still runs on auto. Is it possible to wire the blower fan at the thermostat so the blower run according to what the large window unit is keeping the room temp a...
- Tue Nov 17, 2009 11:02 am
- Forum: Nordyne Service & Repair
- Topic: Intertherm Electric
- Replies: 5
- Views: 3124
Re: Intertherm Electric
Thanks again Robert. I have 2 different limit switches. #6262610 and #6262600. Would the limit switch part number you gave me still replace both switches?
Thanks
Bob
Thanks
Bob
- Thu Nov 12, 2009 5:06 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm Electric
- Replies: 5
- Views: 3124
Re: Intertherm Electric
Thanks Robert. I was hoping it would be the 01-0843 Sequencer Just curious why is the # 901076
so much more $ then the 01-0843? Anyway thanks for the help and will order. Not a big rush yet still warm in North Carolina.
Bob
so much more $ then the 01-0843? Anyway thanks for the help and will order. Not a big rush yet still warm in North Carolina.
Bob
- Mon Nov 09, 2009 12:13 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm Electric
- Replies: 5
- Views: 3124
Intertherm Electric
Hi, Hope you can help me. Heater is a around a 1991 Intertherm electric model #FEH-020HA-04. Problem: Low heat temp. Heater Goes through all cycles fine. Did some tests with meter. transformer-240v on line side. around 26v on load side sequencer no call for heat... h1/h2=0vac h3/h4=0vac all m termin...