Search found 13 matches

by Mikew
Mon Jan 11, 2010 6:31 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Latest
Just got home for the "cabin" was 46 inside when we got there. Heater was putting out approx 90. Then got over 100 when the room warmed up. So guess it is working like he said he should.

Again, thanks
by Mikew
Tue Jan 05, 2010 8:32 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Did stay up there until the house warmed up, will check it out next time up with 70++ temps inside. For now just going to live with it and use the wood stove as we have.

Again

thanks for all your help with this.
by Mikew
Sat Jan 02, 2010 1:26 am
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

I was putting out 90 with house temp at 45 degrees.
by Mikew
Thu Dec 31, 2009 7:47 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Tech came this morning, burn for this furnace is correct, and temp increase is within limits. The unit is 70 BTU and house is 1350 and at 2,000 feet elevation. The unit might be undersized for the temps at this elevation. So at this point at least know that it is working as it is suppose too. So wit...
by Mikew
Mon Dec 28, 2009 8:30 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Service on Thursday will let you know what is found,

mike
by Mikew
Mon Dec 28, 2009 12:20 am
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Thanks for all your help, I will try and find one that can work on it.

mike
by Mikew
Sun Dec 27, 2009 1:37 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

From the service manual.

temp rise is 45-75 degrees.
by Mikew
Sun Dec 27, 2009 1:58 am
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

I think I might be wanting more from this unit than it is capable of. When we go up in the winter it is 40 inside the home and the air coming out the registers is basically warm. We also light the wood stove fire and withing two hours with both units going the temp it up to 73-75 in the living area....
by Mikew
Sun Dec 27, 2009 1:51 am
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Did not check roof jack, This was installed by fuqua when they made the home.

the return air temp was probably about 70-73.

mike
by Mikew
Sat Dec 26, 2009 10:07 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Also the burner is honey combed.
by Mikew
Sat Dec 26, 2009 9:03 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Robert
we just got home, the burner was clean. I did spend more time looking at the flame. It is blue out of the burner, then when it strikes the plate it turns orange.

Also the temp coming out of the closest outlet was 101.

mike
by Mikew
Fri Dec 04, 2009 12:51 am
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Re: Model # M1MB-070A-BW

Thanks, we will be going up in the next couple of weeks and pull it out and check / clean it
by Mikew
Mon Nov 30, 2009 4:32 pm
Forum: Nordyne Service & Repair
Topic: Model # M1MB-070A-BW
Replies: 22
Views: 6452

Model # M1MB-070A-BW

This unit starts and runs just fine, But I do not think the flame is correct. There is blue right at the regulator outlet and lots of orange surrounding it. Seems to take a long time to heat the 1350 sq ft. home. Should there be any orange in the combustion area. There is no AC attached currently. I...