HI,
Yes that furnace is able to upgrade to add a/c. You will need to add an "A" coil and the condensing unit out side as well as a blower upgrade.
Bill
Search found 100 matches
- Mon Jun 06, 2011 10:06 pm
- Forum: Nordyne Service & Repair
- Topic: Miller Model MGHA-056ABFC-05 A-Coil Compatibility
- Replies: 1
- Views: 3726
- Mon Jun 06, 2011 9:48 pm
- Forum: Nordyne Service & Repair
- Topic: switching control boards
- Replies: 4
- Views: 4952
Re: switching control boards
Hi, Very sorry about the amount of time it took to respond to your question. I do have some good news. Here is a link to the part that should work for you. http://www.aberdeenhomerepair.com/store/product/2963/902987-4-7-wire-a%7B47%7Dc-relay-box 4-7 wire control box package used when adding a/c or a...
- Sun Jun 05, 2011 1:51 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Blows 3amp fuse when on Cool only
- Replies: 1
- Views: 2405
Re: Coleman Blows 3amp fuse when on Cool only
Hi Pete, I am not convinced that the reversing valve this the problem. For starters it takes 24 volts to run the valve so putting 12 volts to it wont give you the correct reading. Also by putting on a 4 wire t-stat that wont run the heat pump in a/c mode. But if you are sure that it is your reversin...
- Sun Jun 05, 2011 1:29 pm
- Forum: Nordyne Service & Repair
- Topic: E2EB 015 Blower Problem
- Replies: 1
- Views: 2376
Re: E2EB 015 Blower Problem
Hi, Does your fan come on when you put the thermostat to just fan on? It almost sounds like it could be a fan relay or your blower capacitor.
Thanks Bill
Thanks Bill
- Wed Jun 01, 2011 9:33 pm
- Forum: All Other HVAC Questions
- Topic: furnace issue's
- Replies: 9
- Views: 16039
Re: furnace issue's
Hi,
Tell him what you just said, That you want the problem fixed and don't want the smell anymore. As far as how much it cost, I can't say as every part of the country is different and all repairs are different. Sorry no help there.
Bill
Tell him what you just said, That you want the problem fixed and don't want the smell anymore. As far as how much it cost, I can't say as every part of the country is different and all repairs are different. Sorry no help there.
Bill
- Wed Jun 01, 2011 9:24 pm
- Forum: All Other HVAC Questions
- Topic: ac runs non stop
- Replies: 13
- Views: 6969
Re: ac runs non stop
Hi, Cleaning the outside unit will not help your air flow. what it will do is work more efficiently, It will cool or heat(heat pump) the air better. Sorry but it wont solve your air flow problem. Some item's to check, the insulation under the home, connection of the duct work, Even check the air fil...
- Fri May 27, 2011 9:23 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Presidential II, M/N 3115A751: A/C won't turn on
- Replies: 3
- Views: 4914
Re: Coleman Presidential II, M/N 3115A751: A/C won't turn on
Hi, I would recommend getting more than one quote, Most company's will give you a free quote. A couple of suggestions, Ask the first company that you had come out if the repair bill that you already paid will be taken off the price of the replacement cost. A lot of company's will do this just to get...
- Wed May 25, 2011 10:42 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Presidential II, M/N 3115A751: A/C won't turn on
- Replies: 3
- Views: 4914
Re: Coleman Presidential II, M/N 3115A751: A/C won't turn on
Hi, First thing to do is find out if you have power to the a/c unit. You can start by checking the fuse or breaker at the electrical panel and make sure that the breaker is not tripped or the fuse not blown. If you know that you have power to the a/c unit then it might be the capacitor. Another plac...
- Tue May 24, 2011 7:45 pm
- Forum: All Other HVAC Questions
- Topic: furnace issue's
- Replies: 9
- Views: 16039
Re: furnace issue's
Hi, I am not an expert in kerosene furnaces. But no your furnace should not smell out of the vents. You stated that your furnace is older, and as with any older furnace the heat exchanger is problem the cause of your problem. The reason i say this, even if your not burning all the fuel in the heat e...
- Mon May 23, 2011 9:39 pm
- Forum: Coleman Service & Repair
- Topic: coleman model DGAA070BDTA
- Replies: 2
- Views: 2404
Re: coleman model DGAA070BDTA
Hi, It sounds to me like its the thermostat. The easiest way to check that is to try and jump the a/c at the control board in the furnace and see if it comes on. If it does then i would start with a new stat.
Thanks,
Bill
Thanks,
Bill
- Wed May 18, 2011 7:49 pm
- Forum: All Other HVAC Questions
- Topic: have to replace my unit
- Replies: 6
- Views: 5948
Re: have to replace my unit
HI, I do have a Trane Heat pump and a 95% natural gas furnace. I would recommend a heat pump paired with electric heat or a 80% gas furnace(propane or natural). I don't know where you live but, where i live the power company offers a rebate on the purchase of the heat pump and a lower electrical rat...
- Mon May 16, 2011 9:43 pm
- Forum: All Other HVAC Questions
- Topic: have to replace my unit
- Replies: 6
- Views: 5948
Re: have to replace my unit
Well I have installed both Trane and Goodman equipment. Trane is a better Brand in my opinion. Goodman seams to be just a step below as far as quality goes. There is nothing wrong with Goodman. I am not sure how the warranties compare. Your salesman should be able to show you the difference in warra...
- Fri May 13, 2011 8:40 pm
- Forum: All Other HVAC Questions
- Topic: have to replace my unit
- Replies: 6
- Views: 5948
Re: have to replace my unit
Hi, It is a Big investment to replace your heating and cooling unit for your home. Its true that you might be able to find the same equipment for a much lower amount. You are not paying for just the equipment but for the installation for the equipment the warranty the new duct work and all the elect...
- Wed May 11, 2011 7:52 pm
- Forum: All Other HVAC Questions
- Topic: AC cubic footage question
- Replies: 1
- Views: 2244
Re: AC cubic footage question
Hi Carl, When you go to buy your new window air the box that the unit come's in has the size of the unit and what size of room that it will cool. Keep in mind that, when choosing a room air conditioner, size is important. A unit that is too small will run continually without cooling the room effecti...
- Tue May 10, 2011 7:27 pm
- Forum: Nordyne Service & Repair
- Topic: Blower runs real slow
- Replies: 2
- Views: 12897
Re: Blower runs real slow
Hi, Allen It sounds to me like the blower is not working right. Here is how to check it Turn off the power to the furnace at the circuit-breaker box. Remove the blower cover panel from the furnace housing by removing the screws and lifting the panel out. Locate the blower fan wheel and attempt to sp...