Search found 54 matches

by Lifted79chevy350
Sun Oct 10, 2010 10:18 pm
Forum: Mobile Home Repair
Topic: new to Nail Gun update......
Replies: 1
Views: 981

Re: new to Nail Gun update......

Build a green house or a picnic bench
by Lifted79chevy350
Sun Oct 10, 2010 10:17 pm
Forum: Mobile Home Repair
Topic: Aluminum Wiring
Replies: 4
Views: 1779

Re: Aluminum Wiring

If you get all the wiring replaced keep the aluminum wire and take it to a recycle center. Aluminum is worth a decent amount of cash if your up to it.
by Lifted79chevy350
Sun Oct 10, 2010 10:10 pm
Forum: Mobile Home Repair
Topic: Exterior Paint
Replies: 2
Views: 1391

Re: Exterior Paint

Lorne is right on that about using a good primer even if you don't spend a lot on the paint primer is of up most importance. I would recomend Kwall or valspar on paint if you can afford it if not you can get color palace from walmart which is made by Sherman Williams.
by Lifted79chevy350
Sun Oct 10, 2010 9:58 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

I will go ahead and replace them all. And im not going to leave the site its like a library to me =). Im sure i will be looking for more help on something else. I may also be able to help out someone else.
by Lifted79chevy350
Sat Oct 09, 2010 12:37 am
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

Robert i must say that im really irritated at myself I was looking at the complicated stuff not thinking about the little stuff. I pulled the blower unit out and that little plate on the bottom was flipped around so i took it out and fliped it the other way and it works just fine. The fan wasnt flow...
by Lifted79chevy350
Fri Oct 08, 2010 8:22 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

Sorry Robert i typed it wrong. The limit switch is a L150-20 and i replaced it with a 1 source they both have the same numbers on them 7660-3591. The fan switch is 120-30 (7700-328).
by Lifted79chevy350
Thu Oct 07, 2010 5:26 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

it says 120-20 so im assuming its 120 to 200 but the heat coming out of the vent is only at 104ish and the unit is not getting overly hot i can set my hand on the blower and below the blower and hold it there and the bottom by the little pilot window is a bit warmer can put my hand on there but cant...
by Lifted79chevy350
Thu Oct 07, 2010 1:30 am
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

ok well i tried that it was clean. Still doing the same thing. I have double checked all the wires and connections even looked for cracks on the exchanger and nothing. I looked down in the heater and saw the lower switch nothing seems to be blocking it or anything. I ran it and that lower switch kee...
by Lifted79chevy350
Wed Oct 06, 2010 10:39 am
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

OK i havent dont this before ill look and see. Any hints or tips on this other than make sure power and gas are off.?
by Lifted79chevy350
Tue Oct 05, 2010 12:21 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

Yeah i will try and back trace it today.
by Lifted79chevy350
Tue Oct 05, 2010 9:56 am
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

ok I will do that today and try and back track it.
by Lifted79chevy350
Mon Oct 04, 2010 4:31 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

I replaced the lower limit switch with the same one new and still doing the same thing. Also the t stat dosent stop the call for heat unitl the right temp is reached. I turned the furnace on and used my temp gun and the air coming out of the vent reached a temp of about 104. then the exchanger shuts...
by Lifted79chevy350
Mon Oct 04, 2010 12:46 am
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

well i jumpered it like you said and the exchanger heated up fan kicked on and i heard that limit switch click but with the jumper wire in there it ran like it did before i cleaned the blower out.
by Lifted79chevy350
Sun Oct 03, 2010 11:59 pm
Forum: Coleman Service & Repair
Topic: Coleman runs longer after cleaning blower.
Replies: 29
Views: 8127

Re: Coleman runs longer after cleaning blower.

yeah i hear a click and the signal to the valve goes to 0 the click is coming from lower limit switch.