Hi,
Do you have heat only or heat and a/c ?
IF you have a/c, does it do this in cool mode also ?
Thanks,
robert
Search found 6413 matches
- Sat Feb 26, 2011 12:07 am
- Forum: Coleman Service & Repair
- Topic: Coleman EB Series Furnace / Filter Problems
- Replies: 1
- Views: 2100
- Fri Feb 25, 2011 11:59 pm
- Forum: Coleman Service & Repair
- Topic: Coleman EB15B continues to trip breaker
- Replies: 3
- Views: 2509
Re: Coleman EB15B continues to trip breaker
Hi,
That may or may not be the cause, so watch it closely.
Thanks,
Robert
That may or may not be the cause, so watch it closely.
Thanks,
Robert
- Wed Feb 23, 2011 8:30 pm
- Forum: Coleman Service & Repair
- Topic: Deluxe Blend Air II Damper Motor
- Replies: 16
- Views: 9784
Re: Deluxe Blend Air II Damper Motor
Hi David,
Thanks for update, glad it is operational again.
Take care and best wishes,
Robert
Thanks for update, glad it is operational again.
Take care and best wishes,
Robert
- Wed Feb 23, 2011 8:27 pm
- Forum: Coleman Service & Repair
- Topic: Catching on fire
- Replies: 1
- Views: 1892
Re: Catching on fire
Hi Jodi,
No recalls on that furnace. You will definitely need an hvac tech to thoroughly inspect and properly diagnose.
Find one who is reputable, but beware of last one. It should not ever cost $500 to diagnose a furnace problem.
Thanks,
Robert
No recalls on that furnace. You will definitely need an hvac tech to thoroughly inspect and properly diagnose.
Find one who is reputable, but beware of last one. It should not ever cost $500 to diagnose a furnace problem.
Thanks,
Robert
- Tue Feb 22, 2011 11:05 pm
- Forum: All Other HVAC Questions
- Topic: Furnace way to loud. Moving it back 3 feet.
- Replies: 8
- Views: 10675
Re: Furnace way to loud. Moving it back 3 feet.
Hi,
You're very welcome, happy to help.
Take care and best wishes,
Robert
You're very welcome, happy to help.
Take care and best wishes,
Robert
- Tue Feb 22, 2011 11:03 pm
- Forum: Coleman Service & Repair
- Topic: 7995-316 making ticking noise
- Replies: 3
- Views: 2538
Re: 7995-316 making ticking noise
Hi,
You're very welcome , happy to help.
P.S. A humble attitude is the best attitude of all !!!
Thanks,
Robert
You're very welcome , happy to help.
P.S. A humble attitude is the best attitude of all !!!
Thanks,
Robert
- Mon Feb 21, 2011 3:47 pm
- Forum: Coleman Service & Repair
- Topic: model DGAT075BDF Won't stay lit
- Replies: 1
- Views: 1918
Re: model DGAT075BDF Won't stay lit
Hi William,
That is often due to a dirty or misaligned remote flame sensor.
You can carefully inspect ceramic shroud for cracks and clean sensor rod with steel wool.
Do not touch with bare hands. Turn power off first.
Thanks,
Robert
That is often due to a dirty or misaligned remote flame sensor.
You can carefully inspect ceramic shroud for cracks and clean sensor rod with steel wool.
Do not touch with bare hands. Turn power off first.
Thanks,
Robert
- Mon Feb 21, 2011 3:25 pm
- Forum: Coleman Service & Repair
- Topic: Blower
- Replies: 13
- Views: 6720
Re: Blower
Hi Don, IF you purchased the sequencer from us, it may be covered under the warranty IF the sequencer itself is bad. Getting 24vac across H1 and H2 is what energizes M1/M2 and M3/M4 and closes them. You will read 240vac before they close and 0vac after they close. You stated M1/M2 is still reading 2...
- Sun Feb 20, 2011 11:04 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm ID
- Replies: 1
- Views: 2495
Re: Intertherm ID
Hi Gord,
Data sticker should be on lower electrical component panel cover. WITH a call for heat from t-stat, you should have 240vac across each element coil after about 30/45 seconds.
Test end terminals on white ceramic insulators.
Sequencer is most common problem.
Thanks,
Robert
Data sticker should be on lower electrical component panel cover. WITH a call for heat from t-stat, you should have 240vac across each element coil after about 30/45 seconds.
Test end terminals on white ceramic insulators.
Sequencer is most common problem.
Thanks,
Robert
- Sun Feb 20, 2011 10:59 pm
- Forum: Coleman Service & Repair
- Topic: Need Allergy Filters for Colman Evcon Presidential Furnace
- Replies: 1
- Views: 1695
Re: Need Allergy Filters for Colman Evcon Presidential Furna
Hi,
Call Mark @ 605-229-2627 to see if he has those or can get them. Probably be quicker to contact a local hvac contractor.
Thanks,
Robert
Call Mark @ 605-229-2627 to see if he has those or can get them. Probably be quicker to contact a local hvac contractor.
Thanks,
Robert
- Sun Feb 20, 2011 10:57 pm
- Forum: Coleman Service & Repair
- Topic: Pilot Assembly & Gas Valve for Coleman Model 8610D
- Replies: 1
- Views: 2152
Re: Pilot Assembly & Gas Valve for Coleman Model 8610D
Hi,
Forwarded your email to Mark. Doubt he can help, but figured I'd at least try.
Thanks,
Robert
Forwarded your email to Mark. Doubt he can help, but figured I'd at least try.
Thanks,
Robert
- Sun Feb 20, 2011 10:52 pm
- Forum: Coleman Service & Repair
- Topic: Blower
- Replies: 13
- Views: 6720
Re: Blower
Hi Don,
Sequencer is bad. M1/M2 should read 0vac.
M1/M2 controls one element coil and the blower motor in auto.
Do you need ordering info for the sequencer ?
Thanks,
Robert
Sequencer is bad. M1/M2 should read 0vac.
M1/M2 controls one element coil and the blower motor in auto.
Do you need ordering info for the sequencer ?
Thanks,
Robert
- Sun Feb 20, 2011 10:48 pm
- Forum: All Other HVAC Questions
- Topic: Furnace way to loud. Moving it back 3 feet.
- Replies: 8
- Views: 10675
Re: Furnace way to loud. Moving it back 3 feet.
Hi,
Don't remember the question, but it appeared to be concerning return air. Do not get that confused with combustion air to the burner.
Thanks,
Robert
Don't remember the question, but it appeared to be concerning return air. Do not get that confused with combustion air to the burner.
Thanks,
Robert
- Sun Feb 20, 2011 10:40 pm
- Forum: Nordyne Service & Repair
- Topic: A-coil help needed
- Replies: 3
- Views: 3136
Re: A-coil help needed
Hi,
When first installed, it is matched with outdoor condensing unit.
Later on, it may be replaced by same or a compatible coil.
Usually the a-coil is a half ton larger than the condensing unit for a heat pump.
What is your furnace model number ?
Thanks,
Robert
When first installed, it is matched with outdoor condensing unit.
Later on, it may be replaced by same or a compatible coil.
Usually the a-coil is a half ton larger than the condensing unit for a heat pump.
What is your furnace model number ?
Thanks,
Robert
- Sun Feb 20, 2011 3:01 am
- Forum: Coleman Service & Repair
- Topic: Coleman EB15 heater not working
- Replies: 4
- Views: 2819
Re: Coleman EB15 heater not working
Hi Dave,
You're very welcome, happy to help. Glad it is taken care of.
Thanks,
Robert
You're very welcome, happy to help. Glad it is taken care of.
Thanks,
Robert