Re: Nordyne MGHA-090ABPQ-01 T-stat A/C on/off
Hi Schoolie Well let me start off with , YOU DA MAN! Good job on the wiring job. I am pretty sure that the way you have it working is not going to cause any problems. I have a big book of furnace wiring guides and i was looking at your furnace and they way you have it wired and the way the guide sho...
- Mon Jul 25, 2011 8:24 pm
- Forum: Coleman Service & Repair
- Topic: coleman evcon DRHQ0301BD system
- Replies: 2
- Views: 2449
Re: coleman evcon DRHQ0301BD system
Hi,
I need the make and model number of your furnace so that i can look up error codes.
Thanks
Bill
I need the make and model number of your furnace so that i can look up error codes.
Thanks
Bill
- Mon Jul 25, 2011 8:21 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne MGHA-090ABPQ-01 T-stat A/C on/off
- Replies: 5
- Views: 7525
Re: Nordyne MGHA-090ABPQ-01 T-stat A/C on/off
Hi, First off lets go over how a thermostat wires up. For a heat(gas) and cool thermostat you have 4 or 5 wires that need to hook up. R, Y, G, W, and sometimes depending on the thermostat C. The R terminal is for power to your thermostat. The Y terminal is to control your A/C. The G terminal is for ...
- Mon Jul 25, 2011 7:28 pm
- Forum: Nordyne Service & Repair
- Topic: Problems once again
- Replies: 4
- Views: 3914
Re: Problems once again
Hi, Trish I would like to start with some simple checks first. Check the breaker at the fuse box. Check both A/C and Furnace breaker to see if they tripped when the power came back on. Next Check to see if there is a switch and a fuse on the furnace somewhere. The fuse is covered by a little box, if...
- Fri Jul 22, 2011 9:54 pm
- Forum: Nordyne Service & Repair
- Topic: 1996-ish Intertherm Outside AC Unit won't Force Air
- Replies: 3
- Views: 3348
Re: 1996-ish Intertherm Outside AC Unit won't Force Air
Hi Keith,
Before I can help you out I need to know what the model numbers of the Furnace and of the A/C. Then i will explain what and how air flow and cooling works.
Thanks,
Bill
Before I can help you out I need to know what the model numbers of the Furnace and of the A/C. Then i will explain what and how air flow and cooling works.
Thanks,
Bill
- Fri Jul 22, 2011 9:04 pm
- Forum: All Other HVAC Questions
- Topic: central air system
- Replies: 1
- Views: 2233
Re: central air system
Hi Mark, Here is a coil that will fit your furnace. http://www.aberdeenhomerepair.com/store/product/2274/96-8W4X-OP-A-coil-2.5-5-ton-sweat-R22 This is a sweat coil if you need a quick connect fitting coil just tell them and they will get you the right one. Now as far as a a/c unit. All i can say is ...
- Fri Jul 22, 2011 8:53 pm
- Forum: Nordyne Service & Repair
- Topic: Cleaning Intertherm unit floor ducts
- Replies: 11
- Views: 42739
Re: Cleaning Intertherm unit floor ducts
Hi Dave, I don't a great answer for ya. Sorry. But i am going to toss my two cents in. First I don't recommend putting any kind of liquid in your vents. If you have "Ductboard" duct duct work under your trailer you don't want any liquid on it. That will do more harm than good. Second idea ...
- Sun Jul 17, 2011 10:32 am
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon 4431a901 won't come on
- Replies: 2
- Views: 2253
Re: Coleman Evcon 4431a901 won't come on
Hi, Sounds like you got it all under control. If i could just add one thing, make sure that you clean the outdoor unit. By doing this it makes the a/c work better and will last longer. What i like to do is use a garden hose and just let the water come out at normal pressure and just work my way from...
- Sun Jul 17, 2011 10:25 am
- Forum: Nordyne Service & Repair
- Topic: heat and ac on at same time
- Replies: 4
- Views: 5096
Re: heat and ac on at same time
Hi,
If i remember right it does have the position markings on it. So that should help you out.
Good luck and let me know how it works for ya
Bill
If i remember right it does have the position markings on it. So that should help you out.
Good luck and let me know how it works for ya
Bill
- Fri Jul 15, 2011 9:17 pm
- Forum: All Other HVAC Questions
- Topic: Replacing Thermostat
- Replies: 6
- Views: 7167
Re: Replacing Thermostat
Hi, I just read the user manual for your thermostat and there does not appear to be any way to adjust the settings on the comfort points. I do know this, most thermostats will turn on and satisfy with in 1 or 2 degrees of the set point that you choose. Some thermostat give you the ability to adjust ...
- Thu Jul 14, 2011 4:58 pm
- Forum: Nordyne Service & Repair
- Topic: E3EB-012 Capacitor issue?
- Replies: 2
- Views: 3056
Re: E3EB-012 Capacitor issue?
Hi and Welcome, Here is a link to the capacitor that you are looking for http://www.hvacpartstore.com/2807.html I do believe that this is something that you are able to change out yourself. 1. Turn off all electrical supply circuits to the furnace at the main service panel. 2. Remove furnace front d...
- Tue Jul 12, 2011 4:40 pm
- Forum: Nordyne Service & Repair
- Topic: heat and ac on at same time
- Replies: 4
- Views: 5096
Re: heat and ac on at same time
Hi,
I have good new for you, Here is link for the sequencer that you are looking for
http://www.aberdeenhomerepair.com/store ... 8621678%29
I think that should take care of your problem. Hope this helps
Bill
I have good new for you, Here is link for the sequencer that you are looking for
http://www.aberdeenhomerepair.com/store ... 8621678%29
I think that should take care of your problem. Hope this helps
Bill
- Wed Jul 06, 2011 4:56 pm
- Forum: Nordyne Service & Repair
- Topic: HELP - Intertherm Propane Conversion
- Replies: 2
- Views: 5217
Re: HELP - Intertherm Propane Conversion
Hi, I have checked into the conversion kit that you asked about, What i found is that they don't make a l.p. conversion kit for a furnace that old, But you can find a orifice for it. Not that will do you any good with out the right spring. As a matter of fact the gas burner for that furnace is not a...
- Tue Jul 05, 2011 10:38 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne E2EH 017HA AC coil freezing up
- Replies: 1
- Views: 5432
Re: Nordyne E2EH 017HA AC coil freezing up
Hi, Sorry to hear about your problem. Lets see if i can help you out. First off is to figure out if you need 2 tons or 1.5 tons of cooling. I am going to side with the tech that you had out and say you only need 1.5 tons of cooling. Now let me tell you why. If you put a bigger blower on the furnace ...
- Tue Jul 05, 2011 10:11 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Presidential II AC does not engage.
- Replies: 3
- Views: 7087
Re: Coleman Presidential II AC does not engage.
Hi again, i am guess that you don't have the owner manual for this furnace. So I have a link that will help you. http://www.hvacmanuals.com/store/product/45/Coleman-3100-Series-Electric-Furnace-Manual The manual has it all the wiring diagram and parts diagram. It show you where the fan relay is. Hop...