Coleman DGAH077BBSB FIXED!
Did a pre-season test Friday 10/18/13 and Coleman DGAH077BBSB / LP furnace failed to come on. Viewed 3 green flashes on control panel diagnostic codes. Searching around THIS WEBSITE, found quick tip about the booster motor, aka induced draft motor (IDM) not working do to possible corrosion. SO, I removed 4 screws on black IDM cover, pulled cover away from opening in IDM assembly. The motor has 3 screws that hold it in the tube. I do not think it is possible to remove the motor without removing the entire assembly. I removed 2 of the 3 visible screws holding the motor to the assembly (one is in the back and inaccessible). This loosened it enough to drop it down 1-2" and see the fan blades on the top of the motor. I used a shop-vac on BLOW to spin the fan blades for 5-10 seconds. Then I reassembled all screws, turned on power to furnace, set thermostat. The IDM came on and the furnace operated normally. Thanks to one piece of info found here! Wow! ![Very Happy :D](./images/smilies/icon_biggrin.gif)
![Very Happy :D](./images/smilies/icon_biggrin.gif)
Good deal!!! The motor will come out. If you ever have to do that again, look into the bottom of the assembly. You will see 2 machine nuts, they hold the motor to that 3 screw bracket. Remove the machine nuts, the motor will fall away from the bracket. Remove the 3 screws holding the bracket and then remove the bracket and motor with blade attached from the tube. Easy to oil the bearings once everything is apart.
-
- Similar Topics
- Replies
- Views
- Last post
-
- 2 Replies
- 60177 Views
-
Last post by jazsimpson
Sat Jul 08, 2017 8:16 am
-
- 0 Replies
- 57445 Views
-
Last post by Montanan
Wed Jan 03, 2018 1:03 pm
-
- 0 Replies
- 50013 Views
-
Last post by Kourgath
Fri Mar 23, 2018 3:41 pm
-
-
LOUD Blower on Coleman Presidential 2 900759
by AuntKatie » Thu Apr 05, 2018 6:50 pm » in Coleman Service & Repair - 0 Replies
- 44735 Views
-
Last post by AuntKatie
Thu Apr 05, 2018 6:50 pm
-
-
-
Eb12eb Coleman furnace 4 speed help.
by Johnwayne892000 » Thu Aug 30, 2018 7:37 pm » in Coleman Service & Repair - 0 Replies
- 24909 Views
-
Last post by Johnwayne892000
Thu Aug 30, 2018 7:37 pm
-